Source note3 min read
When Derived Measurements Mislead: Quantifying and Mitigating LLM Over-Trust with Privileged-Modality Reliability Evidence
Source
arXiv
arxiv.org/abs/2607.28421v1
Source
- Source name: arXiv
- Source kind: paper
- Authors / organization: Zongheng Guo, Tao Chen, Tianli Li, Mingzhe Cui, Yang Jiao, Lei Xie, Yi Pan, Xiao Hu, Manuela Ferrario
- Venue: arXiv: cs.AI
- Published: 2026-07-30
- Collected: 2026-07-31
- URL: http://arxiv.org/abs/2607.28421v1
- PDF: https://arxiv.org/pdf/2607.28421v1
- DOI: UNKNOWN
Plain-Language Brief
The study presents a framework to quantify and address Derived-Feature Over-Trust (DFOT), which occurs when large language models (LLMs) misuse derived measurements as if they were direct facts. The researchers use physiological sensing as a case study, testing the acceptance of a PPG-derived rhythm contradicted by offline ECG and the rejection of a reliable PPG rhythm under misleading severe history. The framework includes five estimators to assess this chain, with the results showing improvement in four repair and specificity endpoints when using ECG-to-PPG privileged distillation as a baseline.
What the Document Says
- The study defines Derived-Feature Over-Trust (DFOT) as the failure of a downstream LLM to correctly use or interpret derived measurements within their valid scope.
- Physiological sensing is used as a case study to test the acceptance of a PPG-derived rhythm contradicted by offline ECG and the rejection of a reliable PPG rhythm under misleading severe history.
- ECG supplies training supervision and offline reference construction but is never shown to the LLM.
- Five estimators are used: conflict over-trust rate (COTR), context-induced error rate (CIR), correct repair rate (CRR), evidence-specific repair margin (ESRM), and utility harm rate (UHR).
- The framework is independent of a particular reliability generator.
- The study demonstrates the framework using 50,000 paired PPG-ECG records, with ECG-to-PPG privileged distillation as an illustrative baseline and PPG-only inference.
- On a protocol-locked 187-patient test, the baseline improves four repair and specificity endpoints by 1.82-6.69 percentage points, with all paired confidence intervals excluding zero; UHR increases by 0.67 percentage points (95% CI: -0.4 to +1.7).
- The study's code is available at https://github.com/Zongheng-Guo/When-Derived-Measurements-Mislead.
Key Concepts Mentioned
- Derived-Feature Over-Trust (DFOT)
- large language models (LLMs)
- physiological sensing
- ECG
- PPG-derived rhythm
- offline ECG
- privileged distillation
Claims Made by the Document
- DFOT occurs when downstream LLMs misuse derived measurements.
- The proposed framework can quantify DFOT and provide a common evaluation target for stronger mitigation methods.
Evidence Used
- The study defines DFOT and outlines the framework to address it.
- The results of the study demonstrate improvement in repair and specificity endpoints when using ECG-to-PPG privileged distillation as a baseline.
Methods / Approach
UNKNOWN
Limitations Stated by the Authors
UNKNOWN
Limitations Noted by the Agent
Agent interpretation — not from the source.
UNKNOWN
Open Questions
UNKNOWN
Notes for Future Q&A
May include interpretation. Labeled where it does.
UNKNOWN
Raw Abstract / Excerpt
Derived measurements increasingly enter large language model (LLM) pipelines as direct facts despite their instance-dependent validity. We define derived-feature over-trust (DFOT) as the failure in which a downstream LLM assigns such a measurement the epistemic status of a direct fact or uses it outside its valid scope. Using physiological sensing as a case study, D1 tests acceptance of a PPG-derived rhythm contradicted by offline ECG, whereas D2 tests rejection of an offline-confirmed reliable PPG rhythm under misleading severe history. ECG supplies training supervision and offline reference construction but is never shown to the LLM. Five estimands quantify this chain: conflict over-trust rate (COTR) and context-induced error rate (CIR) characterize D1/D2; correct repair rate (CRR) measures frozen-error repair; evidence-specific repair margin (ESRM) contrasts matched and patient-disjoint shuffled evidence; and utility harm rate (UHR) measures unnecessary verification among HIGH-reliability cases used without verification at baseline. The framework does not depend on a particular reliability generator. We demonstrate it on 50,000 paired PPG-ECG records using ECG-to-PPG privileged distillation as an illustrative baseline and PPG-only inference. On a protocol-locked 187-patient test, the baseline improves four repair and specificity endpoints by 1.82-6.69 percentage points, with all paired confidence intervals excluding zero; UHR increases by 0.67 percentage points (95% CI: -0.4 to +1.7). DFOT provides a common evaluation target for stronger mitigation methods. The code is available at https://github.com/Zongheng-Guo/When-Derived-Measurements-Mislead.